The step of tensile testing of the zipper by the tensile testing machine

10-10-2019

Ulabester's self-developed and produced UTM Universal Testing Machine are widely used, mainly for footwear, leather, clothing, textiles, rubber and other materials. Tensile, tearing, peeling, compression, bending, anti-shearing, three points Various physical properties such as bending resistance.

 

The Universal Tensile Testing Machine is used to detect the flat pull strength of the zipper, which can be divided into seven major steps:

 

一.the purpose of the test: to detect the flat pull strength of the zipper.

二.the test range: This test method is applicable to all types of zippers.

三.the test equipment: Dual Column computerized universal testing machine


Universal Tensile Testing Machine

四.the parameter requirements: tensile machine speed: 300mm / min


五.the test steps:

1. The sample is parked in the laboratory environment for more than 8 hours.

2. Intercept three zippers with a length of ≥75mm.

3. Start the power of the tension machine and set the speed to 300mm/min. The sample device is placed between the upper and lower clamps, and the device should be aligned with the pinch portion of the fastener element and the clamp.

4. Start the tensile test button. Start the test and test until the tooth is removed or the tape is broken. Record the maximum tensile force during the test.

5. Test each sample at least 3 times and take the average as the final result.


六.Calculation or judgment of results:

Flat pull strength (kg) = maximum pull force (kg) * 25mm / tensile machine clamp width (mm)


七.the tensile testing equipment test flat tension test notes:

1. If all three values are acceptable, the average of the three values is used as the final result.

2. If one of the three values is unqualified, it is necessary to revise two samples for re-inspection. If there is any unqualified in the re-inspection, it is judged as unqualified, and the unqualified value of the initial inspection and the re-examination is The average is taken as the final result. If the retest does not fail, all pass numbers are used as the final result.

3. If two or more of the three values are unqualified, it is judged as unqualified, and the average value of the unqualified values is taken as the final result.

Get the latest price? We'll respond as soon as possible(within 12 hours)